Test & Data Engineer

Palmer, Massachusetts, United States

IMI plc
We are a global specialist engineering company that creates breakthrough solutions. We are curious and like to solve problems, partnering with our customers to solve the demands of today and prepare for the challenges of tomorrow. We embrace innovation and care about outcomes that are good for business, everyday life and making a better world – creating lasting impact for everyone.

We design, build and service highly engineered products in fluid and motion control applications. We focus on five market sectors: Industrial Automation, Process Automation, Climate Control, Life Science, and Transport.

Our partnership approach breaks through problems and reduces complexity. We don’t invent in isolation – we collaborate with our customers. We listen closely and we think differently, creating space for diverse minds to innovate. We are working together to make businesses safer, more sustainable and more productive.

Role Overview

The Test & Data Engineer is the technical owner for manufacturing test capabilities and engineering data systems at the Palmer site. The role develops and validates test methods, fixtures, instrumentation, automation, and data pipelines used to characterize and release precision life science products, including electron multipliers, filaments, microchannel plate assemblies, and related mass spectrometry and vacuum components.

The engineer converts test results into clear technical decisions that improve product performance, manufacturing yield, reliability, and launch readiness. Success in this role means reliable test systems, traceable data, faster failure diagnosis, and actionable insights for Engineering, Quality, and Operations.

Work Environment: Palmer, MA; Onsite

Key Responsibilities

Test System Development & Technical Ownership

  • Develop, document, validate, and maintain electrical, mechanical, vacuum, and functional test methods for new and existing products.
  • Design and implement test fixtures, interfaces, tooling, interlocks, and automated or semi-automated test stations suitable for a mixed-volume manufacturing environment.
  • Select and integrate instrumentation for high-voltage, low-current, noise, gain, resistance, temperature, pressure, vacuum, dimensional, and life-test measurements as applicable to the product.
  • Define test requirements, acceptance criteria, calibration needs, sampling plans, uncertainty limits, and preventive-maintenance standards. Lead equipment qualification and test-method validation, including IQ/OQ/PQ, correlation studies, Gauge R&R, and measurement uncertainty analysis.

Data Engineering, Analytics & Reporting

  • Develop reliable data acquisition and handling workflows that capture test conditions, serial or lot traceability, results, failure modes, and equipment status.
  • Develop and maintain data-analysis scripts, queries, dashboards, and automated reports using tools such as Python, SQL, Power BI, Excel, LabVIEW, or equivalent platforms.
  • Establish data-quality controls, version control, access controls, and retention practices to ensure accurate, traceable, and reproducible engineering data.
  • Analyze test results, process variation, drift, cycle time, yield, retest and false-failure rates, equipment utilization, and product performance using statistical and reliability methods to identify improvement opportunities and provide actionable recommendations.

Manufacturing Support & Failure Analysis

  • Provide hands-on technical support for test equipment and product failures on the manufacturing floor, prioritizing production-impacting issues.
  • Lead structured root-cause investigations using methods such as 5 Why, Fishbone, fault-tree analysis, FMEA, 8D, and controlled experimentation.
  • Improve first-pass yield and reduce scrap, retesting, troubleshooting time, and operator dependency through improved diagnostics, error-proofing, and test-process optimization.
  • Partner with Manufacturing Engineering and Quality on nonconforming material disposition, containment, and corrective actions. Train technicians and operators on test methods, equipment use, distinguishing product from measurement-system failures, data interpretation, and escalation standards.

Product Characterization, Validation & Reliability

  • Plan and execute engineering studies, pilot builds, qualification testing, design verification, process validation, and product-comparison testing.
  • Develop characterization plans that translate customer and design requirements into measurable critical-to-quality outputs and statistically justified acceptance criteria. Coordinate life, stress, environmental, and performance testing as required.
  • Analyze customer returns and field-performance data to correlate production test results with actual product performance and improve screening effectiveness.
  • Support equipment transfers, new product introduction, process and engineering changes, and production ramp-up. Participate in design reviews, PFMEA, control-plan development, APQP or stage-gate reviews, and launch-readiness assessments to ensure test readiness and data coverage.

Compliance, Documentation & Continuous Improvement

  • Create and maintain controlled test procedures, work instructions, software configurations, validation protocols, technical reports, and equipment records.
  • Ensure test systems and records comply with applicable customer requirements, the site quality-management system, ISO standards, ESD controls, electrical safety practices, and data-integrity expectations.
  • Support internal, customer, and certification audits by providing evidence of test-method control, calibration, validation, traceability, and corrective actions.
  • Standardize test architectures, data structures, dashboards, and engineering methods across product families while driving continuous improvement in safety, quality, delivery, cost, and technical capability through disciplined change control.

Health, Safety & Environmental (HSE) Responsibilities

  • Follow all applicable Health, Safety and Environmental (HSE) requirements and safe work practices.
  • Identify and report hazards, near misses, incidents and unsafe conditions.
  • Actively contribute to a positive HSE culture and continuous improvement.

Critical Competencies for Success

  • Engineering & Technical Expertise: Test-method development, fixture and station design, instrumentation, automation, electrical and functional troubleshooting, validation, and qualification.
  • Data & Software: Python or equivalent scripting, SQL, data acquisition, visualization, automated reporting, and version-controlled technical work.
  • Statistical Analysis & Problem-Solving: Measurement-system analysis (MSA), Gauge R&R, SPC, DOE, capability analysis, regression, hypothesis testing, and reliability and trend analysis.
  • Manufacturing & Continuous Improvement: Hands-on production support, root-cause analysis, FMEA, corrective actions, Lean problem-solving, and mixed-volume manufacturing.
  • Technical Communication: Controlled documentation, technical reporting, visual dashboards, and clear presentation of risks, evidence, conclusions, and recommended actions.

Required Qualifications

  • Bachelor's degree in Electrical Engineering, Mechanical Engineering, Mechatronics, Computer Engineering, Manufacturing Engineering, Physics, or a related technical discipline.
  • Four or more years of engineering experience involving test development, instrumentation, data acquisition, automation, product characterization, or manufacturing support.
  • Hands-on experience developing or validating test methods, fixtures, equipment, or automated measurement systems.
  • Proficiency in engineering data analysis using Python, SQL, Minitab, MATLAB, R, Power BI, advanced Excel, or comparable tools, with demonstrated practical capability in at least two.
  • Working knowledge of measurement-system analysis, SPC, DOE, capability analysis, and structured root-cause methods.
  • Ability to interpret electrical schematics, mechanical drawings, test specifications, and technical requirements and translate them into executable test plans.
  • Ability to work onsite in laboratory and manufacturing environments and safely support test systems involving electrical, thermal, vacuum, mechanical, or chemical hazards as applicable.

Preferred Qualifications

  • Experience with LabVIEW, National Instruments hardware, PLCs, microcontrollers, automated instrumentation, or custom test-software development.
  • Experience testing electron multipliers, filaments, microchannel plates, detectors, vacuum components, mass spectrometry hardware, high-voltage devices, or other low-signal precision products.
  • Experience with databases, manufacturing execution systems, electronic device history or traceability systems, and automated dashboard deployment.
  • Experience with reliability testing, accelerated life testing, uncertainty analysis, calibration systems, and test-equipment correlation.
  • Experience in life science, medical device, semiconductor, aerospace, analytical instrumentation, or another regulated or technically demanding manufacturing environment.
  • Six Sigma Green Belt, Certified Quality Engineer, LabVIEW certification, or equivalent demonstrated capability.

What IMI Can Offer You
At IMI, one of our top priorities is to create an inclusive culture of health. We strive to remove barriers to care (whether that be physical or financial) and in doing so, we offer choice for all your health and wellbeing needs. 

See below for a general overview of our amazing perks and benefits:

  • Multiple health plans to choose from: HMO, PPO, and High Deductible Health Plans with a low-cost share
  • Best-in-class 401K plan with zero vesting and up to 6% contribution matching
  • 14-week maternity leave at full pay following one year of service (Adoption benefits are equivalent)
  • 4-week paternity leave at full pay following one year of service (Adoption benefits are equivalent)
  • Employee Resource Groups that offer community and support, like our Pride Network and Network of Women groups 
  • PTO, encompassing inclusive holidays 
  • Career Development opportunities (IMI’s ‘Catalyst’ Program)
  • Employer contribution for Health Savings Account, and in many cases free virtual telemedicine, and teletherapy.
  • Mental Health and wellness programs to support you and your family
  • Full suite of voluntary benefits to tap into, including but not limited to: Critical illness insurance, hospital indemnity, legal insurance, identity theft protection, and pet insurance or home & auto insurance through our discount advantage platform
  • Short & long-term disability as well as basic life insurance at 2x your basic salary at no cost to the employee
  • Free financial advisors, webinars, and classes through Charles Schwab
  • Annual Employee Stock Purchase Plan with option to purchase IMI shares at a reduced employee only price - no opportunity to lose, only to profit or refund your investment 100%

**Benefits plans change year over year, but we have guiding principles in place to ensure our employees have the tools and resources available to stay connected and up to date**

Health & Safety

The physical demands described within the Key Duties & Responsibilities section of this job description are required to perform the essential functions of this position.  Reasonable accommodations may be made for individuals with disabilities.  Please contact your local HR representative to discuss the specific Work Conditions and Physical Requirements of this role.  

Health, Safety, and Environmental Duties – At IMI we are all personally committed to protecting our people, minimizing our impact to the environment, the communities we operate in and our company. All members of our workforce have the duty to ensure the health, safety and welfare of themselves, others, and the environment. Every employee is expected to follow all HSE operating procedures, also to challenge any observed behaviors or unsafe acts.

Code of Ethics

IMI requires the highest standard of ethics in all business dealings, particularly with customers, suppliers, advisors, employees, and the authorities. In accordance with the IMI Way: Our Code of Responsible Business.

Changes to This Job Description

IMI may amend this job description in whole or part at any time.

IMI is an equal opportunity employer. Qualified applicants will be considered without regard to age, race, creed, color, national origin, ancestry, marital status, affectional or sexual orientation, gender identity or expression, disability, nationality, sex, or veteran status.

Ready to apply?

Resume *